ELECTRONIC CONTROL PANEL
Page 15
DUPLEX/TRIPLEX ECO PARALLEL:
The 2/3 Simplex systems, that make up a Duplex/Triplex
system, must be programmed individually; the program
does NOT necessarily have to be the same on the 2/3 Simplex
systems!
1. Press the scroll
button and hold it for 5 sec until the
display shows:
2. Within 10 sec, press the up
button; the display will
show:
Press the up
or down
button to set the hardness
unit. Make sure to also adjust/convert the exchange
capacity!
3. Press the scroll
button again; the display will show:
Press the up
or down
button to set the
exchange capacity per litre of resin.
4. Press the scroll
button again; the display will show:
Press the up
or down
button to set the volume
of resin.
5. Press the scroll
button again; the display will show:
Press the up
or down
button to set the number
of days between regenerations.
6. Press the scroll
button again; the display will show:
Press the up
or down
button to set the length
of the regeneration cycle.
Press the scroll
button again to advance to the next
regeneration cycle.
7. Press the scroll
button again; the display will show:
Press the up
or down
button to set the type of
water meter sensor.
8. Press the scroll
button again; the display will show:
Press the up
or down
button to set the
regeneration mode:
Immediate: when the remaining capacity equals
0, an immediate regeneration is started.
Dlyd/Immd: when the remaining capacity equals
the reserve capacity, a delayed regeneration at
the programmed time of regeneration is started;
however when the remaining capacity equals 0
before the programmed time of regeneration is
reached, an immediate regeneration is started.
Delayed: when the remaining capacity equals the
reserve capacity, a delayed regeneration at the
programmed time of regeneration is started.
9. Press the scroll
button again; the display will show
(only when the regeneration mode is set to ‘Delayed’ or
‘Dlyd/Immd’):
Press the up
or down
button to set the time of
regeneration.
10. Press the scroll
button again; the display will show
(only when the regeneration mode is set to ‘Delayed’ or
‘Dlyd/Immd’):
Press the up
or down
button to set the reserve
capacity:
Variable: the reserve capacity is calculated
automatically, based on the registered daily water
usage.
Fxd: press the scroll
button again and press the
up
or down
button to set the reserve
capacity to a fixed amount.
11. Press the scroll
button again; the display will show:
Press the up
or down
button to save the
program into the NOVRAM® and exit the
programming level.
12. Repeat steps 1-11 for all Simplex systems.
Cycle 1: XX min
System Check
HardUnit:°f
Resin:XXX liters
ExCap:5.5°f M3/L
Override: 7 days
MTR:SNAP SENSOR
Regen:Immediate
Rsrv Variable
Regen @ 2:00
Exit